GATE EC Control Systems Formula Sheet
Organised by the official GATE 2027 EC syllabus, Section 6: Control Systems. Each worked example was checked in code. Practise these: GATE EC Control Systems previous year questions.
Feedback, transfer functions and block diagrams
Syllabus: Basic control system components; feedback principle; transfer function; block diagram representation; signal flow graph.
Closed-loop transfer function
- Symbols
- : forward-path transfer function
- : feedback-path transfer function
- : loop transfer function
- Applies when
- Single loop, negative feedback. With positive feedback the denominator is 1 − GH.
- Common mistake
- Using 1 + G in the denominator when H ≠ 1.
- Worked example
- G = 10/(s + 1), H = 1: the DC gain: 0.909 (10/11)
Sensitivity to the plant
- Symbols
- : fractional change in T per fractional change in G
- Applies when
- Evaluated at a frequency (often DC). Feedback with large loop gain makes T insensitive to G; sensitivity to H approaches −1.
- Common mistake
- Thinking feedback reduces sensitivity to the sensor H as well. It doesn't: T ≈ 1/H.
- Worked example
- Loop gain GH = 99: 0.01
Mason's gain formula
- Symbols
- : gain of the k-th forward path
- : loop gains; the sums of products are over non-touching loops
- : Δ with the loops touching path k removed
- Applies when
- Any linear signal flow graph. Products in Δ are only over loops that share no node.
- Common mistake
- Including touching loops in the product terms of Δ.
- Worked example
- Forward path G₁G₂; loops −G₁H₁ and −G₂H₂, not touching; G₁ = 2, G₂ = 3, H₁ = H₂ = 1: 0.5 (6/12)
Transient and steady-state analysis
Syllabus: Transient and steady-state analysis of LTI systems.
Second-order step response
- Symbols
- : damping ratio, between 0 and 1
- : natural frequency (rad/s)
- : peak overshoot, as a fraction
- Applies when
- Standard form ²/(s² + 2ζ s + ²), underdamped, no zeros. Rise time and settling time are approximations.
- Common mistake
- Using the 5% settling rule (3/ζ) when the question asks for 2%.
- Worked example
- ζ = 0.5, = 10 rad/s: overshoot: 16.3 % ( = 0.363 s, ≈ 0.8 s)
Steady-state error and error constants
- Symbols
- : open-loop transfer function with unity feedback
- : position, velocity and acceleration constants
- Applies when
- Unit step, unit ramp and unit parabola inputs, unity negative feedback, and a stable closed loop (check that first).
- Common mistake
- Quoting an error constant for an unstable closed loop, where there is no steady state.
- Worked example
- G = 10/(s(s + 2)), unit ramp: 0.2 ( = 5)
Stability, frequency response, Bode and root locus
Syllabus: Frequency response; Routh-Hurwitz and Nyquist stability criteria; Bode and root-locus plots.
Routh-Hurwitz for a cubic
- Symbols
- : coefficients of the characteristic polynomial
- Applies when
- A third-order characteristic equation. When = exactly, a pair of roots sits on the jω axis at ω = √.
- Common mistake
- Checking only that all coefficients are positive, which is necessary but not sufficient from third order on.
- Worked example
- s³ + 2s² + 3s + K: the largest K for stability: 6 (oscillates at √3 rad/s when K = 6)
Nyquist criterion
- Symbols
- : closed-loop poles in the right half-plane
- : clockwise encirclements of −1 by G(jω)H(jω)
- : open-loop poles in the right half-plane
- Applies when
- The Nyquist contour encloses the whole right half-plane, detouring round open-loop poles on the jω axis.
- Common mistake
- Counting counter-clockwise encirclements as positive: with Z = N + P, N counts clockwise ones.
- Worked example
- GH = 10/(s + 1)³: unstable closed-loop poles: 2 (P = 0, N = 2)
Gain and phase margins
- Symbols
- : phase crossover: where the phase is −180°
- : gain crossover: where |GH| = 1
- Applies when
- Minimum-phase systems: stable when both margins are positive.
- Common mistake
- Reading the gain margin at the gain crossover frequency instead of the phase crossover.
- Worked example
- GH = 2/(s(s + 1)(s + 2)): gain margin: 9.54 dB ( = √2, |GH| = 1/3)
Bode asymptotes
- Symbols
- : time constant; the corner is at ω = 1/T
- Applies when
- Real poles and zeros. The asymptote is 3 dB off at the corner; a pole at the origin gives −20 dB/decade from the start.
- Common mistake
- Adding the slope change at the wrong corner, or forgetting a pole at the origin.
- Worked example
- 1/(1 + jω) at ω = 1: -3.01 dB
Root locus asymptotes and breakaway
- Symbols
- : open-loop poles and zeros
- : numbers of poles and zeros
- : gain, from 1 + KG(s)H(s) = 0
- Applies when
- For K from 0 to ∞ (negative feedback). Branches start at the poles and end at the zeros or along the asymptotes.
- Common mistake
- Taking any root of dK/ds = 0 as a breakaway point: it must lie on a part of the real axis that belongs to the locus.
- Worked example
- Poles 0, −1, −2, no zeros: the centroid: -1 (asymptotes at 60°, 180° and 300°; breakaway at −0.423)
Compensators, PID and state variables
Syllabus: Compensators, PID controller; state variable model and solution of state equation of LTI systems.
Lead compensator
- Symbols
- : ratio of the pole to the zero frequency
- : maximum phase lead
- : where it occurs (rad/s)
- Applies when
- Lead: zero below the pole, adding phase near crossover. A lag compensator has α < 1. A PID controller is + /s + s.
- Common mistake
- Putting the maximum phase at the arithmetic mean of the corners: it is at their geometric mean.
- Worked example
- α = 10: 54.9 ° of maximum lead
Transfer function from a state model
- Symbols
- : state, input, output and feed-through matrices
- Applies when
- LTI state model. The poles of G(s) are among the eigenvalues of A.
- Common mistake
- Writing B(sI − A)⁻¹C: the order is C, then the inverse, then B.
- Worked example
- A = [[0, 1], [−2, −3]], B = [0; 1], C = [1, 0], D = 0: G(0): 0.5 (G = 1/(s² + 3s + 2))
State transition matrix
- Symbols
- : state transition matrix
- Applies when
- LTI systems. Φ(0) = I and Φ(t₁ + t₂) = Φ(t₁)Φ(t₂).
- Common mistake
- Taking e^(At) entry by entry: the exponential of a matrix is not the matrix of exponentials.
- Worked example
- A = [[0, 1], [−2, −3]]: Φ₁₁ at t = 1: 0.6004 (2e^(−t) − e^(−2t))
Controllability and observability
- Symbols
- : number of states
- Applies when
- LTI state models. Full rank of the first matrix means controllable; of the second, observable.
- Common mistake
- Building the controllability matrix with powers of A on the wrong side: it is AB, not BA.
- Worked example
- A = [[0, 1], [−2, −3]], B = [0; 1]: rank of [B AB]: 2 (controllable)
Practise these: GATE EC Control Systems previous year questions
Source for the section headings: the official GATE 2027 EC syllabus, IIT Madras. The formulas, examples and notes are Studyloaf's own.